Gas Sensors MQ-2 MQ-3 MQ-4 MQ-5 MQ-6 MQ-7 MQ-8 MQ-9 Module
MQ-2:
Detection concentration: 300-1000ppm(combustible gas).
Gas may be used in homes and factories leakage monitoring device suitable for the detection of gas, butane , propane , methane , smoke , etc. ;
Module Features :
1 using high-quality dual-panel design, with power indicator and TTL signal output instructions ;
2 the switching signal having a DO (TTL) output and analog output AO ;
3 TTL output valid signal is low . ( Low-level signal when the output light can be directly connected to the microcontroller or relay module )
4 analog output voltage with the higher concentration of higher voltage.
5 a gas, natural gas, city gas , smoke better sensitivity.
6 there are four screw holes for easy positioning ;
7 Product dimensions : 32 (L) * 20 (W) * 22 (H)
8 has a long life and reliable stability
9 rapid response and recovery characteristics
Electrical properties:
Input voltage : DC5V Power consumption ( current ): 150mA
DO output : TTL digital 0 and 1 ( 0.1 and 5V)
AO output :0.1-0 .3 V ( relative to pollution ) , the maximum concentration of a voltage of about 4V
Special note: After the sensor is powered , needs to warm up around 20S, measured data was stable , heat sensor is a normal phenomenon , because the internal heating wire , if hot is not normal .
Wiring:
1, VCC: positive power supply (5V)
2, GND: power supply is negative
3, DO: TTL switching signal output
4, AO: analog signal output
MQ-3:
Used in motor vehicles and other no drunken drivers homework personnel on-site testing, also used in other places of ethanol vapor detection.
Feature:
Size: 32 x 22 x 27mm
Main chip: LM393, ZYMQ - 3 gas sensors
Working voltage: DC 5V
1, With a signal output instructions.
2, Two-way signal output (TTL level output and analog output)
3, TTL output signal for low level effectively.(when the low output electric signal lights at ordinary times, can be directly by single chip microcomputer)
4, Analog 0 - 5V voltage, the higher the concentration, the higher the voltage.
5, To ethanol steam has a high sensitivity and good selectivity.
6, In June and has long service life and reliable stability.
7, Rapid response recovery features.
MQ-4:
1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, The analog output voltage, the higher the concentration the higher the voltage.
5, Methane, natural gas has better detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
Electrical properties:
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V
MQ-5:
Suitable for home or industrial on LPG, natural gas, coal gas monitoring devices. Excellent resistance to alcohol, smoke interference.
Module Features:
1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, The analog output voltage, the higher the concentration the higher the voltage.
5, For gas, natural gas has better detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32* 20 * 22
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
Electrical properties:
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V.
MQ-6:
Suitable for domestic or industrial on LPG (liquefied petroleum gas), butane, propane, LNG (liquefied natural gas) detection devices. Excellent resistance to ethanol vapor, smoke interference.
Module Features:
1, Using high-quality dual-panel design, with power indicator and TTL signal output instructions;
2, With a DO switch signal (TTL) output and AO analog signal output;
3, TTL output valid signal is low. (When the output low signal light can be directly connected microcontroller or relay module)
4, 0 ~ 5V analog output voltage, the higher the concentration the higher the voltage.
5, The propane, butane, LPG, LNG has a good detection sensitivity.
6, There are four screw holes for easy positioning;
7, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
8, With a long service life and reliable stability
9, Rapid response and recovery characteristics
Electrical properties:
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V
MQ-7:
For home, carbon monoxide detection device environment. Suitable for carbon monoxide and gas detection.
Module Features:
Detection of concentration: 10-1000ppmCO
Loop voltage Vc: <=10V DC
Heater voltage Vh: 5.0V ±0.2V ACorDC(high)
Load resistance: adjustable.
Heater resistance RH: 31ohm ± 3 ohm(room temperature)
Heater power consumption PH: <=350mW
Standard test conditions:
Temperature: 20 degree ± 2 degree
Humidity: 65% ± 5% RH
Standard test circuit: Vc: 5.0V ± 0.1V; Vh(high):5.0V±0.1V
Vh(low):1.5V±0.1V
1, The analog output voltage, the higher the concentration the higher the voltage.
2, The carbon monoxide detection with better sensitivity.
3, There are four screw holes for easy positioning;
4, Product Dimensions: 32 (L) * 20 (W) * 22 (H)
5, With a long service life and reliable stability
6, Rapid response and recovery characteristics
Electrical properties:
Input voltage: DC5V power (current): 150mA
DO output: TTL digital 0 and 1 (0.1 and 5V)
AO output :0.1-0 .3 V (relatively clean), the highest concentration of voltage around 4V
MQ-8:
Suitable for domestic or industrial hydrogen leak on a monitoring device. Are not subject to ethanol vapor, soot, carbon monoxide and other gases interference.
MQ-9:
For home or factory gas leak detection device, suitable for carbon monoxide, combustible gas monitoring device.
Can test carbon monoxide: 10 to 1000ppm CO
Combustible gas range: 100 to 10000ppm
Module Features:
Loop voltage Vc: <=10V DC
Heater voltage Vh: 5.0V ±0.2V ACorDC
Heater resistance: 31 ohm ± 3 ohm(room temperature).
Heater power consumption PH: <=900mW
Standard test conditions:
Temperature: 20 degree ± 2 degree
Humidity: 65% ± 5% RH
Standard test circuit: Vc: 5.0V ± 0.1V
Vh:5.0V±0.1V
Warm up time: more than 48 hours.